AVR - Automatic Voltage Regulator R250
The AVR R250 is an analogue transistorised automatic voltage regulator designed to control the excitation current in Leroy Somer brushless alternators (LSA series 42.2 to 47.2). This AVR, which adapts to the shunt excitation system, guarantees a voltage regulation of approximately ±0.5%. Its simple concept allows efficient self-excitation even when the alternator has no short-circuit capacity.
The R250 operates on a supply range of 85 to 139 V and is compatible with frequencies of 50 Hz and 60 Hz, incorporating adjustment thresholds for different load levels and protection against speed variations and load fluctuations. It complies with international standards such as IEC, VDE, NEMA, BS, CSA and UL508 low-voltage CE. In addition, it has a potentiometer for voltage adjustments, and custom programmes are available on request.
AVR - R250 belongs to the generator excitation circuit and holds the output voltage within about ±1 % when the load steps up or down.
AVR wear is thermal. It works inside the generator compartment with no ventilation of its own, so it is usually the first module to age on a high-hour set. Keeping one on the shelf avoids a multi-day stop for a low-cost part.
Specifications and compatibility
- Applicable to
- LEROY SEMER
- Dimensions
- 170 x 650 x 130 mm
- Weight
- 1.00 kg
How to verify before ordering
- Check that the reference printed on the AVR label (for example AS440, MX341, R120) matches exactly; variants differ in sensing range and excitation level.
- Confirm the excitation input voltage and the generator type it serves. They are not interchangeable across generator makes or speed ranges.
- Inspect wiring and brushes before replacing the module: a loose connection produces exactly the same symptoms as a burnt AVR.
Frequently asked questions
How do I know the fault is the AVR and not the generator?
Measure output voltage at steady load. If it is low and does not respond to the excitation trim, while windings and rotating diodes are healthy, the AVR is the suspect. A cross-test with a spare AVR confirms it in minutes.
Can the voltage be trimmed after installation?
Yes. Most of these regulators have a voltage and a stability trim pot. Set them at no load to the site nominal voltage, then verify under load before signing off.
Related parts
- AVR - Automatic Voltage Regulator R220
- AVR - Automatic Voltage Regulator R120
- AVR - Automatic Voltage Regulator R449
- AVR - Automatic Voltage Regulator MX341
- AVR - Automatic Voltage Regulator R450
See the spare parts catalogue or request a quotation quoting the equipment reference. Third-party trademarks are cited for identification purposes only.
Specifications
| Characteristics | |
|---|---|
| Model | R250 |
| Applicable To | LEROY SEMER |
| Weight | 1,00 kg |
| Dimensions | 170 x 650 x 130 mm |
| Spare Parts | |
|---|---|
| Generator Parts | AVR |