Molded case circuit breaker - BCP-M3 Series 1250L-3300/4300 1250A 3P/4P
Circuit Breaker BCP-M3 1250L 1250A 3P/4P is a circuit breaker: it opens on overload or short circuit, protecting the generator, the cabling and the downstream load.
A breaker should not trip in normal service. If it opens at the usual load, the cause is nearly always a mis-set trip, loose terminals generating heat, or a breaker sized below the real set current.
Specifications and compatibility
- Brand
- BCP
- Type
- Moulded case circuit breaker
- Electrical type
- Moulded Case Circuit Breaker (MCCB)
- Amperage
- 1250 A
- Pole
- 3P/4P
How to verify before ordering
- Match rated current, trip curve (B/C/D) and breaking capacity to the circuit it protects.
- Check whether the panel uses a moulded case, DIN rail or open-frame breaker, and how many poles.
- Confirm the kA rating: fitting one below the original leaves the panel unprotected against short circuit.
Frequently asked questions
Why does the breaker trip when the set starts?
The motor inrush or the transformer magnetising current crosses the instantaneous threshold. It is solved with the right curve (type D or a short-delay setting), not by raising the rating without recalculating the cable.
Can I replace it with a higher amperage one?
Not without recalculating cable and alternator. A larger breaker leaves the cable unprotected and pushes the damage into the winding.
See the spare parts catalogue or request a quotation quoting the equipment reference. Third-party trademarks are cited for identification purposes only.
Circuit Breaker BCP-M3 1250L 1250A 3P/4P is a circuit breaker: it opens on overload or short circuit, protecting the generator, the cabling and the downstream load.
A breaker should not trip in normal service. If it opens at the usual load, the cause is nearly always a mis-set trip, loose terminals generating heat, or a breaker sized below the real set current.
Specifications and compatibility
- Brand
- BCP
- Type
- Moulded case circuit breaker
- Electrical type
- Moulded Case Circuit Breaker (MCCB)
- Amperage
- 1250 A
- Pole
- 3P/4P
How to verify before ordering
- Match rated current, trip curve (B/C/D) and breaking capacity to the circuit it protects.
- Check whether the panel uses a moulded case, DIN rail or open-frame breaker, and how many poles.
- Confirm the kA rating: fitting one below the original leaves the panel unprotected against short circuit.
Frequently asked questions
Why does the breaker trip when the set starts?
The motor inrush or the transformer magnetising current crosses the instantaneous threshold. It is solved with the right curve (type D or a short-delay setting), not by raising the rating without recalculating the cable.
Can I replace it with a higher amperage one?
Not without recalculating cable and alternator. A larger breaker leaves the cable unprotected and pushes the damage into the winding.
See the spare parts catalogue or request a quotation quoting the equipment reference. Third-party trademarks are cited for identification purposes only.
Specifications
| Pole | 3P, 4P |
| Brand | BCP |
| Amperage (A) | 1250 A |