The AVC125-10 AVR regulates the excitation level supplied to the field of a conventional brushless synchronous generator. Regulation is achieved by sensing the generator output voltage, converting it into a DC signal and comparing that signal with a reference voltage. An error signal is developed and used to control the DC field power in order to maintain a constant generator output. Each regulator includes frequency compensation with selectable slope, inverse-time over-excitation shutdown, build-up circuits, single- or three-phase voltage sensing, single- or three-phase shunt or permanent magnet generator (PMG) power input, parallel droop compensation and an accessory input. The accessory input provides compatibility with devices such as var/power factor controllers or excitation limiters.

$ 447.14 447.14 USD Tax Excluded

447.14 Bs Tax Excluded

  • Model
  • Generator Parts
  • Applicable To
  • Weight
  • Dimensions

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

AVR - AVC125-10 is the automatic voltage regulator of the generator: it reads the output voltage and corrects the field excitation so the voltage stays stable as the load changes.

A failing AVR shows up before it dies: voltage dips 5–30 V when a large motor starts, lights flicker, or the control panel reboots. When it fails completely the set delivers only residual voltage or trips on overvoltage.

Specifications and compatibility

Applicable to
BASLER ELECTRIC
Dimensions
22 x 6 x 13 cm
Weight
1.50 kg

How to verify before ordering

  • Check that the reference printed on the AVR label (for example AS440, MX341, R120) matches exactly; variants differ in sensing range and excitation level.
  • Confirm the excitation input voltage and the generator type it serves. They are not interchangeable across generator makes or speed ranges.
  • Inspect wiring and brushes before replacing the module: a loose connection produces exactly the same symptoms as a burnt AVR.

Frequently asked questions

How do I know the fault is the AVR and not the generator?

Measure output voltage at steady load. If it is low and does not respond to the excitation trim, while windings and rotating diodes are healthy, the AVR is the suspect. A cross-test with a spare AVR confirms it in minutes.

Can the voltage be trimmed after installation?

Yes. Most of these regulators have a voltage and a stability trim pot. Set them at no load to the site nominal voltage, then verify under load before signing off.

Related parts

See the spare parts catalogue or request a quotation quoting the equipment reference. Third-party trademarks are cited for identification purposes only.

Specifications

Characteristics
Model AVC125-10
Applicable To BASLER ELECTRIC
Weight 1,50 kg
Dimensions 22 x 6 x 13 cm
Spare Parts
Generator Parts AVR